holy crap, big, big problems

Any problems with your Ultra sampler should be reported here, hopefully someone might know what's wrong.

Moderators: ezman, stu, Ole

holy crap, big, big problems

Postby wrecker13 » Sun Sep 21, 2003 9:37 am

I recently won a E4XT on Ebay and it supposedly came with an internal SCSI drive. Well there was no icon for it when I booted up so I opened up the EMU to have a look. The SCSI drive was in there but it was not firing up. So I took it out and hooked it up to my other EMU and it worked fine. So I put it back in the E4XT and I heard it turn on when I powered up the unit. But now the EMU isn't booting up completely. The lights come on but the display has a few black lines running across it which is not a good sign. Has anybody had anything like this happen. I think it's probably gonna have to be sent in for service.
wrecker13
 
Posts: 89
Joined: Mon Aug 11, 2003 4:50 am
Location: Boston MA, USA

Postby ezman » Sun Sep 21, 2003 7:37 pm

I had this happen when I put a connector in the wrong way round - opened it back up and put it the other way and it worked fine. Give it a go if that's a possibility. Good luck :thumbs:
Ezman
ezman
 
Posts: 340
Joined: Mon Apr 14, 2003 8:14 pm
Location: Leeds, UK


Return to EOS:Troubleshooting