by mosrob » Sun Jul 22, 2012 11:49 am
As I understand can't EOS load the bank without errors.
Is the error-message really "sample full"???
Try something else:
1. Recreate the bank by merging all banks you used before. Go to Sample Edit, Tools 2 and execute Integrity to fix all imported samples, if necessary.
2. Save this bank.
3. Delete alle Samples via Sample Manage but keep the Presets.
4. Save the Bank that just contains the Presets without the Samples and without replacing the bank you saved under step 2.
5. Clear memory and load the complete bank you saved under step 2.
6. If an error occures, clear memory, import/merge one by one each sample from the bank, saved under step 2 but keep the same sample numbers.
7. Merge the bank with the presets, saved under step 4.
8. Save this bank to a new place and check if the error still occures.